Science Catalog 2012 Life GloMax®-Multi Detection System Product GloMax®-Multi Base Instrument GloMax®-Multi Luminescence Module GloMax®-Multi Fluorescence Module GloMax®-Multi Absorbance Module Available Separately Single Injector System for GloMax®-Multi Detection System Dual Injector System for GloMax®-Multi Detection System GloMax®-Multi Detection System External PC Connect Kit GloMax® Luminometer Light Plate GloMax®-Multi Optical Kit Blue (also included with Cat.# E7051 or E8051) GloMax®-Multi Optical Kit UV (also included with Cat.# E7051 or E8051) GloMax®-Multi Optical Kit Green (also included with Cat.# E7051 or E8051) GloMax®-Multi Optical Kit Red (also included with Cat.# E7051 or E8051) GloMax®-Multi Optical Kit AFC (also included with Cat.# E7051 or E8051) Injector Inlet Tubing Assembly Injector Outlet Tubing Assembly for Single-Injector System Injector Outlet Tubing Assembly for Dual-Injector System Waste Collection Tray GloMax® Injector Tips Replacement USB Flash Drive, 2.0, 2GB GloMax®-Multi Detection System 490nm Absorbance Filter Set 1 each E8922 1170.00 1 each E8923 1170.00 1 each E8924 1170.00 1 each E8917 1206.00 1 set E8925 177.00 1 each E8926 234.00 1 each E8927 324.00 1 each E8928 171.00 1 each E5401 123.00 1 each E8935 Pls. Enq. 1 each E8929 Pls. Enq. GloMax®-Multi Base Instrument Service Agreement 1 each SA3020 Pls. Enq. GloMax® Injectors Service Agreement, 1 year 1 each SA3040 Pls. Enq. For Research Use Only. Not for Use in Diagnostic Procedures. Description: The GloMax®-Multi Microplate Multimode Reader is the next-generation integrated solution from Promega. While maintaining stateof-the-art luminescence performance, the GloMax® line now extends into fluorescence and absorbance applications. By combining assay reagents with a high-performance detection instrument, it’s now easier than ever to start capturing real results. The GloMax®-Multi Detection System consists of a base unit plus modular detection and functional units, allowing a flexible solution that can be expanded over time. Luminescence, fluorescence and absorbance reading modules are available as well as an optional injector system (used with the luminescence detection module only). Luminescence Module: An advanced photon-counting photomultiplier tube (PMT) provides unmatched signal-to-noise ratios, beating most standalone luminometers. The luminescence module can detect as little as 3 × 10–21 moles of luciferase, covering a dynamic range over 8 logs. A dual masking system minimizes well-to-well cross-talk. Size Cat.# Price (Fr) 1 each E7031 Pls. Enq. 1 each E7041 Pls. Enq. 1 each E7051 Pls. Enq. 1 each E7061 Pls. Enq. 1 each E7071 Pls. Enq. 1 each E7081 Pls. Enq. 1 each E8916 Pls. Enq. 1 each E6531 1459.00 1 each E8921 1170.00 GloMax® Multi Multimode Reader Fluorescence Module: Application-optimized Optical Kits simplify fluorescence operation while maximizing performance. Long-lived LED-based excitation lights minimize maintenance and variability in intensity. The UV, Blue, Green, Red and AFC Optical Kits are included with the Fluorescence Detection Module. • UV (Ex: 360nm, Em: 410–460nm) • Blue (Ex: 490nm, Em: 510–570nm) • Green (Ex: 525nm, Em: 580–640nm) • Red (Ex: 625nm, Em: 660–720nm) • AFC (Aminofluorocoumarin; Ex: 405nm, Em: 495–505nm) Absorbance Module: A 6-position filter wheel with 2 open positions ensures flexibility for a wide range of applications. An LED-based visible spectrum light source minimizes maintenance and variability. Filters for reading 450, 560, 600 and 750nm are included. A 490nm filter is available as an accessory. Operation of the GloMax®-Multi Detection System can be performed entirely through the touch screen. Protocols for a variety of Promega and common laboratory assays are pre-installed, and there is also the flexibility to modify the protocols or create new methods. Data can be saved on the instrument and moved via the included USB flash drive. The system works as a standalone workstation in the laboratory, freeing computing resources from data capture, so more resources can be directed toward analysis. Features: • Flexible Configuration: Modular system grows with your needs. • Dedicated Luminometer Performance: Sensitive to approximately 3 × 10–21 moles of luciferase with over 8 logs of dynamic range. • Multiplex Cell-Based Assays: Obtain more data from each experiment. • Fluorescence and Absorbance Capability: Read standard lab assays without compromising luminescence performance. • Engineered to Minimize Sample Cross-Talk: Expect reliable results in all read modes. Protocol GloMax®-Multi Detection System Technical Manual Part# TM297 188 For complete and up-to-date product information visit: www.promega.com/catalog 7253TA Pagina 191

Pagina 193

Voor tijdschriften, online whitepapers en folders zie het Online Touch CMS beheersysteem systeem. Met de mogelijkheid voor een webwinkel in uw publicaties.

Promega Switzerland - Life Sciences Catalog 2012 Lees publicatie 100Home


You need flash player to view this online publication